CE8865-4C is a four-card-slot Huawei CloudEngine 8800 family switch. Huawei identifies 02355RTA as the base chassis without power supplies or fan modules. Other official component codes package two AC supplies and three fan modules with either port-side intake or port-side exhaust; license-bundle codes are also listed separately. The model alone therefore does not establish the delivered power, cooling or software configuration.
Huawei lists CE88-D10CQ-H, CE88-D16CQ-H, CE88-D24T2CQ-H, CE88-D24YS2CQ-H and CE88-D8YS4DQ-H among the supported card families in the hardware description. The documented starting software release for CE8865-4C is V300R023C10. Huawei also states that this device does not support stacking or USB-based deployment, which should be considered when replacing a different CloudEngine platform.
| Exact model / SKU | CE8865-4C |
| Product type | Modular CloudEngine data-center switch chassis |
| Service-card slots | 4 |
| Base component code | 02355RTA; chassis without power supplies or fan modules |
| Starting software release | V300R023C10 |
| Packaged airflow choices | Port-side intake or port-side exhaust, depending on component code |
| Deployment limitations | Stacking and USB-based deployment are not supported |
| Source match | Exact CE8865-4C model and 02355RTA component code in Huawei hardware documentation |
| Official manufacturer reference | Huawei CE8865-4C official hardware description |
| Item | CloudEngine 8865-4C |
| Switching capacity | 16 Tbps |
| Packet forwarding rate | 2400 Mpps |
| Buffer | 64MB |
| Air duct type | Standard front-to-back or back-to-front airflow |
| Device virtualization | M-LAG |
| Port | Jumbo frames |
| Network virtualization | VXLAN routing and VXLAN bridging |
| BGP-EVPN | |
| SDN | iMaster NCE-Fabric |
| Network convergence | PFC and AI ECN |
| RDMA and RoCE (RoCE v1 and RoCE v2) | |
| Programmability | OpenFlow |
| OPS programming | |
| Traffic analysis | NetStream |
| VLAN | Access, trunk, and hybrid ports |
| Default VLAN | |
| MAC address table | Automatic MAC address learning and aging |
| Static, dynamic, and blackhole MAC address entries | |
| Source MAC address filtering | |
| MAC address learning limiting based on ports and VLANs | |
| IP routing | IPv4 dynamic routing protocols such as RIP, OSPF, IS-IS, and BGP |
| IPv6 dynamic routing protocols such as RIPng, OSPFv3, IS-ISv6, and BGP4+ | |
| IPv6 | VXLAN over IPv6 |
| IPv6 VXLAN over IPv4 | |
| IPv6 neighbor discovery (ND) | |
| Path MTU discovery (PMTU) | |
| TCP6, IPv6 ping, IPv6 tracert, IPv6 socket, UDP6, and raw IPv6 | |
| Multicast | Multicast routing protocols such as IGMP, PIM-SM, and MSDP |
| IGMP snooping and IGMP proxy | |
| IPv6 Layer 3 multicast and configuration of both Layer 2 and Layer 3 multicast services | |
| Fast leaving of multicast member interfaces | |
| Multicast traffic suppression | |
| Multicast NAT | |
| Reliability | LACP |
| STP, RSTP, VBST, and MSTP | |
| BPDU protection | |
| Smart link and multi-instance | |
| Hardware-based Bidirectional Forwarding Detection (BFD), with a minimum packet sending interval of 3.3 ms | |
| VRRP, VRRP load sharing, and BFD for VRRP | |
| BFD for BGP, IS-IS, OSPF, and static routing | |
| BFD for VXLAN | |
| Traffic classification based on Layer 2 headers, Layer 3 protocols, and Layer 4 protocol priorities | |
| QoS | ACL, CAR, re-marking, and scheduling |
| Queue scheduling modes such as PQ, DRR, and PQ+DRR | |
| Congestion avoidance mechanisms such as WRED and tail drop | |
| Traffic shaping | |
| IEEE 1588v2 (PTP) | |
| Intelligent O&M | Network-wide path detection |
| Telemetry | |
| Enhanced ERSPAN | |
| In-situ Flow Information Telemetry (IFIT) | |
| Packet Event: packet loss visualization and ultra-long latency visualization | |
| Statistics collection on the buffer microburst status | |
| VXLAN OAM: VXLAN ping and VXLAN tracert | |
| Intelligent lossless network | PFC deadlock prevention |
| AI ECN | |
| ECN Overlay | |
| Enhanced NSLB | |
| Configuration and maintenance | Terminal login through the console port, Telnet, and SSH |
| Network management protocols, such as SNMPv1/v2/v3 | |
| File upload and download through FTP and TFTP | |
| Boot Read-Only Memory (BootROM) upgrade and remote online upgrade | |
| Hot patching | |
| User operation logs | |
| Configuration rollback | |
| ZTP | |
| Security and management | MACsec |
| Command line authority control based on user levels, preventing unauthorized users from using commands | |
| Defense against DoS, ARP, and ICMP attacks | |
| Port isolation, port security, and sticky MAC | |
| Binding of the IP address, MAC address, port ID, and VLAN ID | |
| Authentication methods, including AAA, LDAP, RADIUS, and HWTACACS | |
| RMON | |
| Dimensions (H x W x D) | 88.1 mm x 442.0 mm x 600.0 mm |
| Weight in full configuration | 16.54 kg |
| Environment requirements | Operating temperature: 0°C to 40°C (0 m to 1800 m) Storage temperature: -40°C to +70°C Relative humidity: 5% RH to 95% RH (noncondensing) |
| Operating voltage | 600 W AC and 240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC 1200 W DC power module: -38.4 V DC to -72 V DC; 40 V DC to 57 V DC |
| Typical power consumption | CE8865-4C (configured with four CE88-D16CQ-H cards): 650W (100% load, 32 x 100G copper cables, room temperature, dual AC power supplies) 728W (100% load, 32*100G port short-distance optical module, normal temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D10CQ-H cards): 315W (100% load, 20 x 100G copper cables, normal temperature, dual AC power supplies) 338W (100% load, 20 x 200G copper cables, room temperature, dual AC power supplies) 345W (100% load, 20*100G port short-distance optical module, normal temperature, dual AC power supplies) 420W (100% load, 20*200G short-distance optical modules, room temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D8YS4DQ-H cards): 306W (100% load, 8*400G+16*25G copper cables, room temperature, dual AC power supplies) 406W (100% load,8*400G+16*25G short-distance optical modules, normal temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D24YS2CQ-H cards): 305W (100% load, 48*25G+4*100G copper cables, room temperature, dual AC power supplies) 338W (100% load,48*25G+4*100G short-distance optical modules, normal temperature, dual AC power supplies) CE8865-4C (configured with four CE88-D24T2CQ-H cards): 381W (100% load, 48*10G electrical ports + 4*100G copper cables, room temperature, dual AC power supplies) 388W (100% load, 48*10G electrical modules+4*100G short-distance optical modules, normal temperature, dual AC power supplies) |
| Exact product model | CE8865-4C |
| Product family | Huawei CloudEngine data center switch |
| Official Huawei documentation | Huawei Enterprise Support results for CE8865-4C |
Product Quotation | ![]() | Condition and Packaging | |
Return Eligibility | Returns and Replacement | ||
Shipping Arrangements | ![]() | Warranty Terms |
Huawei CloudEngine 8865-4C Data Center Switch is a HUAWEI CE8800 Series Switches product supplied by YYST Global for enterprise IT procurement and infrastructure projects.
For CE8865-4C, the manufacturer specification lists switching capacity as 16 Tbps.
For CE8865-4C, the manufacturer specification lists packet forwarding rate as 2400 Mpps.
For CE8865-4C, the manufacturer specification lists port as Jumbo frames.
Contact YYST Global to confirm availability for CE8865-4C, the required quantity, exact configuration, delivery destination and current lead time before ordering. A product listing does not confirm current inventory.
Related products

CE8865-SAN-4C is a Huawei CloudEngine storage-network switch with four half-width subcard slots, 16 Tbps switching capacity and 2,400 Mpps forwarding performance. The base CE8865-SAN-4C ordering code is a mainframe without fan or power modules; the B and F bundles include two AC power modules and three fans with different airflow directions.

CE8861-4C-EI has the following distinguishing entries in the manufacturer specification. Weight: ~twenty-eight kg (fully configured). Typical Power Consumption: ~ nine hundred W (depending on line cards). Maximum Power Consumption: ~ one thousand eight hundred W.

CE8860-4C-EI has the following distinguishing entries in the manufacturer specification. Weight: ~thirty kg (fully configured). Typical Power Consumption: ~ eight hundred fifty W (depending on modules). Maximum Power Consumption: ~ one thousand seven hundred W.

CE8868-4C-EI is listed in Huawei CE8800 Series Switches. Check model compatibility, current stock, condition and quotation details.

CE8850-64CQ-EI is Huawei's 64-port 100GE QSFP28 CloudEngine 8800 data center switch. Huawei specifies 12.8 Tbps switching capacity, 4482 Mpps forwarding, and a 42 MB buffer; the base order excludes fan and power modules.

CE8850-32CQ-EI is a Huawei CloudEngine CE8800-series data center switch. Huawei's official Info-Finder identifies the exact model and the CloudEngine software documentation lists V200R002C50 as its minimum release for documented features such as Smart Link, ARP and STP/RSTP.

CE8855-32CQ4BQ is a Huawei data-center switch with 32 QSFP28 100GE optical ports and four QSFP56 200GE optical ports. The official hardware description does not identify these four ports as 400GE; procurement records should use the verified 200GE configuration.

CE8850E-32CQ-EI Dimensions (W × D × H): 442 mm × 600 mm × 43.6/88.1 mm; Weight: ~15–18 kg (depending on configuration); Ports: 32 × 100GE QSFP28 (supports breakout into 4 × 25GE or 2 × 50GE).