Huawei CE6885H-48YS8CQ Switch

CE6885H-48YS8CQ
Price:US $234.00
Huawei CE6885H-48YS8CQ Switch
Huawei CE6885H-48YS8CQ SwitchHuawei CE6885H-48YS8CQ SwitchHuawei CE6885H-48YS8CQ SwitchHuawei CE6885H-48YS8CQ Switch

Huawei CE6885H-48YS8CQ Switch

CE6885H-48YS8CQ

CE6885H-48YS8CQ

New Factory Sealed
US$ 234.00
mastercard paypal t-t visa
Huawei CE6885H-48YS8CQ Switch
Engineer Team Support
7*24h Online
  • 763 412 7282
  • +86 010 82830816

CE6885H-48YS8CQ Overview

CE6885H-48YS8CQ

CE6885H-48YS8CQ (02355SFF)

Overview

Table 4-153 Basic information about the CE6885H-48YS8CQ

ItemDetails
DescriptionCE6885H-48YS8CQ switch (48*25GE SFP28, 8*100GE QSFP28, Without Fan and Power Modules)
Part Number02355SFF
ModelCE6885H-48YS8CQ
First supported versionV300R023C10
Other part numbers

02355SFG(CE6885H-48YS8CQ switch (48*25GE SFP28, 8*100GE QSFP28, 2*AC Power Modules, 5*Fans, Port-side Intake))

02355SFH(CE6885H-48YS8CQ switch (48*25GE SFP28, 8*100GE QSFP28, 2*AC Power Modules, 5*Fans, Port-side Exhaust))

Short NameCE6885H


Figure 4-187 Indicators on the CE6885H-48YS8CQ (power supply side)

CE6885H-48YS8CQ Specification

Technical Specifications

Table 4-157 Technical specifications of the CE6885H-48YS8CQ

ItemSpecification
Dimensions with packaging (H x W x D) [mm (in.)]185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.)
Dimensions without packaging (H x W x D) [mm (in.)]
  • Basic dimensions (the depth excludes the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.5 mm (1.72 in. x 17.40 in. x 17.58 in.)
Weight without packaging [kg (lb)]6.84 kg (15.08 lb), excluding optical modules, power modules, and fan modules
Weight without packaging (full configuration) [kg (lb)]9.03 kg (19.91 lb) (including AC power modules and fan modules but excluding optical modules. If the device supports multiple models of modules, the heaviest modules are used for the measurement.)
Weight with packaging [kg (lb)]11.11 kg (24.49 lb)
Weight with packaging (full configuration) [kg (lb)]13.3 kg (29.32 lb)
Chassis height [U]1 U
Installation TypeCabinet installation
Switching capacityTo obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
CPU16-core, 2 GHz
MemoryDRAM: 16 GB
NOR Flash64 MB x 2
SSD Flash4GB SSD
USB

It can be used for log backup and USB-based deployment.

This function is reserved.

Power supply mode
  • AC pluggable
  • DC pluggable
  • HVDC pluggable
Console portRJ45
Downlink Service interface48 x 25GE SFP28/48 x 50GE SFP56
Uplink Service interface8 x 100GE QSFP28/8 x 200GE QSFP56
Service port supporting the stack functionReserved function. This function is not enabled.
RTCSupported
Typical power consumption [W]

48 x 25GE + 8 x 100GE ports:

207 W (100% traffic load, copper cables on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)

218 W (100% traffic load, short-distance optical modules on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)

Typical heat dissipation [BTU/hour]

48 x 25GE + 8 x 100GE ports:

706 BTU/hour (100% traffic load, copper cables on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)

744 BTU/hour (100% traffic load, short-distance optical modules on 24 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules)

Static power consumption [W]196 W
Static heat dissipation [BTU/hour]669 BTU/hour
Maximum power consumption [W]

48 x 25GE + 8 x 100GE ports:

255 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules)

372 W (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules)

Maximum heat dissipation [BTU/hour]

48 x 25GE + 8 x 100GE ports:

870 BTU/hour (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules)

1269 BTU/hour (100% traffic load, long-distance optical modules on all ports, high temperature, dual AC power modules)

Number of power modules2
Redundant power supply1+1 backup
Rated input voltage [V]
  • 600 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC
  • 1200 W DC power module: –48 V DC to –60 V DC; +48 V DC
  • 400 W DC power module: –48 V DC to –60 V DC; +48 V DC
Input voltage range [V]
  • 600 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC
  • 1200 W DC power module: –38.4 V DC to –72 V DC; +40 V DC to +57 V DC
  • 400 W DC power module: –38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC
Maximum input current [A]
  • 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC)
  • 1200 W DC power module: 38 A (–48 V DC to –60 V DC); 38 A (+48 V DC)
  • 400 W DC power module: 12 A (–48 V DC to –60 V DC); 12 A (+48 V DC)
Rated output power [W]
  • 600 W AC&240 V DC power module: 600 W
  • 1200 W DC power module: 1200 W
  • 400 W DC power module: 400 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Power supply surge protection [kV]

AC: 6 kV in common mode and 6 kV in differential mode

DC: 4 kV in common mode and 2 kV in differential mode

HVDC: 4 kV in common mode and 2 kV in differential mode

Types of fansPluggable
Number of fan modules5
Redundant fansThe device supports 4+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation modeAir cooling
Airflow directionPort-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction.
Availability0.9999948505
MTBF [year]44.34 years
Noise at normal temperature (27°C, sound pressure) [dB(A)]

Front-to-back airflow:

Average: 52.8 dB(A); max: 58.7 dB(A)

Back-to-front airflow:

Average: 51.3 dB(A); max: 59.0 dB(A)

Noise at high temperature (40°C, sound pressure) [dB(A)]

Front-to-back airflow:

Average: 69.5 dB(A); max: 76.0 dB(A)

Back-to-front airflow:

Average: 70.2 dB(A); max: 75.6 dB(A)

Long-term operating altitude [m (ft.)]≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating temperature [°C (°F)]

0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)

NOTE:

When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage altitude [m (ft.)]≤ 5000 m (16404 ft.)
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Storage temperature [°C (°F)]-40ºC to +70ºC (-40°F to +158°F)
RTU License Supported

Yes.

By default, 48 x 25GE ports can only work at the rate of 25 Gbit/s, and eight 100GE ports can only work at the rate of 100 Gbit/s. You can use the RTU license (BOM number: 88036EUQ) to increase the rate of 25GE ports to 50 Gbit/s and the rate of 100GE ports to 200 Gbit/s.

CE6885H-48YS8CQ Warranty

Low Price Guarantee
Customers can get high quality products at wholesale prices

Quality Assurance
All products sold are original genuine goods, new packaging unopened

100% Money Back Guarantee
If your returns meet our relevent standards,you can contact our customer service team to exchange or return any product that you bought from us

Commodity Refund Guarantee
For equipment purchased from us, please contact our customer service team for return and replacement services

Diversified and Flexible Transportation Services
Cargo carriers include Fedex, DHL, UPS, Aramex, TNT, EMS

Standard Policy
1 Year