Huawei CE9865-4C Switch

CE9865-4C
Price:US $445.00
Huawei CE9865-4C Switch
Huawei CE9865-4C SwitchHuawei CE9865-4C SwitchHuawei CE9865-4C Switch

Huawei CE9865-4C Switch

CE9865-4C

CE9865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)

New Factory Sealed
US$ 445.00
mastercard paypal t-t visa
Huawei CE9865-4C Switch
Engineer Team Support
7*24h Online
  • 763 412 7282
  • +86 010 82830816

CE9865-4C Overview

CE9865-4C (02356BCE)

Overview

Table 4-213 Basic information about the CE9865-4C

ItemDetails
DescriptionCE9865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)
Part Number02356BCE
ModelCE9865-4C
First supported versionV300R024C00
Other part numbers

02356BCF(CE9865-4C Mainframe (With 4 Subcard Slots, 2*AC Power Modules, 4*Fans, Port-side Intake))

02356BCJ(CE9865-4C mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card,port-side intake))

02356HYJ(CE9865-4C mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*8 Port 400GE QSFP-DD Interface card,port-side intake))

Short NameCE9865

CE9865-4C Specification

Technical Specifications

Table 4-217 Technical specifications of the CE9865-4C

ItemSpecification
Dimensions with packaging (H x W x D) [mm (in.)]485 mm x 670 mm x 1060 mm (19.09 in. x 26.38 in. x 41.73 in.)
Dimensions without packaging (H x W x D) [mm (in.)]
  • Basic dimensions (the depth excludes the parts protruding from the body): 175 mm x 442 mm x 765 mm (6.89 in. x 17.40 in. x 30.12 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 175 mm x 442 mm x 817.5 mm (6.89 in. x 17.40 in. x 32.19 in.)
Weight without packaging [kg (lb)]28.7 kg (63.27 lb) (excluding fan modules, power modules, and cards)
Weight without packaging (full configuration) [kg (lb)]

34.4 kg (75.84 lb) (with four power modules and four fan modules)

45 kg (99.21 lb) (with four power modules, four fan modules, and four 32-port 100GE cards)

44 kg (97 lb) (with four power modules, four fan modules, and four 8-port 400GE cards)

Weight with packaging [kg (lb)]53.7 kg (118.39 lb) (excluding fan modules, power modules, and cards)
Weight with packaging (full configuration) [kg (lb)]

59.4 kg (130.95 lb) (with four power modules and four fan modules)

70 kg (154.32 lb) (with four power modules, four fan modules, and four 32-port 100GE cards)

69 kg (152.12 lb) (with four power modules, four fan modules, and four 8-port 400GE cards)

Chassis height [U]4 U
Installation TypeCabinet installation
Switching capacityTo obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
CPU16-core, 2 GHz
MemoryDRAM: 16 GB
NOR Flash64 MB x 2
SSD Flash8GB
USBSupported
Power supply mode
  • AC pluggable
  • DC pluggable
  • HVDC pluggable
Console portRJ45
Downlink Service interface

The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards:

CE98-D32CQ-F: 32 x 100GE QSFP28

1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s.

2. Only the top-row ports can be split. Every four ports form a group. When a 40GE/100GE port is split into 4 x 10GE or 4 x 25GE ports, the other top-row port is also split, and the bottom-row ports in the same group become unavailable. For example, ports 1, 2, 3, and 4 form a group. When port 1 is split, port 3 is also split, and ports 2 and 4 are unavailable. Only ports with optical modules can be split, and ports with copper cables cannot be split.

3. Support for optical modules: 40GE-SR4/LR4/eSR4/ER4/BIDI/eSDLC/SDLC/LX4/eSR4 and AOC, as well as 100G-SR4/PSM4/CWDM4/LR4/SWDM4/4WDM/BIDI/LX4/DR1/FR1/LR1/ER4 optical modules are supported. When the ambient temperature ranges from 0°C to 35°C (32°F to 95°F), 100G-ZR4 is supported, but the device noise will exceed the threshold.

4. Support for copper cables: 40GE/100GE 1/3/5 m passive copper cables are supported. Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports.

CE98-D8DQ-F: 8 x 400GE QSFP-DD

1. 400GE ports cannot be configured as 200GE, 100GE, or 40GE ports.

2. A 400GE port can be split into 4 x 100GE or 2 x 200GE ports. Only ports with optical modules can be split, and ports with copper cables cannot be split.

3. Support for optical modules:

(1) 400GE ports support optical modules such as 400GE-SR8/eSR8/SR4/LR8/DR4/FR4/ER8/ZR and AOC.

(2) 400G-ZR+ optical module: When the ambient temperature ranges from 0°C to 35°C (32°F to 95°F), only ports 1, 3, 5, and 7 in slots 3 and 4 support 400G-ZR+ optical modules. Each card supports four 400G-ZR+ optical modules, and a total of eight 400G-ZR+ optical modules are supported. In the ambient temperature, the device noise increases to 83 dBA. Ports 1 and 2, 3 and 4, 5 and 6, and 7 and 8 form different groups. In each group, only the port with a smaller port number supports 400G-ZR+. For example, if a 400G-ZR+ optical module is inserted into port 1, port 2 becomes unavailable and no optical module can be inserted.

(3) 400G-VR4 is supported in V300R024C10 and later versions.

4. Support for copper cables: 400GE 1 m/2.5 m copper cables are supported. (For 400GE 1 m copper cables, only QSFP-DD-400G-CU1M is supported, and QSFP-DD-400G-CU1M-S is not supported.) Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports.

Service port supporting the stack functionNot supported
RTCSupported
Typical power consumption [W]

Configured with four CE98-D32CQ-F cards: 1465 W (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature, fully configured with AC power modules)

Configured with four CE98-D8DQ-F cards: 1140 W (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules)

Typical heat dissipation [BTU/hour]

Configured with four CE98-D32CQ-F cards: 4999 BTU/hour

(100% traffic load, 64-port 100G-SR4 optical modules, normal temperature, fully configured with AC power modules)

Configured with four CE98-D8DQ-F cards: 3890 BTU/hour

(100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules)

Static power consumption [W]

Configured with four CE98-D32CQ-F cards: 1083 W

Configured with four CE98-D8DQ-F cards: 847 W

Static heat dissipation [BTU/hour]

Configured with four CE98-D32CQ-F cards: 3695 BTU/hour

Configured with four CE98-D8DQ-F cards: 2890 BTU/hour

Maximum power consumption [W]

Configured with four CE98-D32CQ-F cards: 1854 W (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature, fully configured with AC power modules)

Configured with four CE98-D8DQ-F cards: 1457 W (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules)

Configured with four CE98-D32CQ-F cards: 2597 W (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules)

Configured with four CE98-D8DQ-F cards: 1831 W (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules)

Maximum heat dissipation [BTU/hour]

Configured with four CE98-D32CQ-F cards: 6326 BTU/hour (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature, fully configured with AC power modules)

Configured with four CE98-D8DQ-F cards: 4971 BTU/hour (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules)

Configured with four CE98-D32CQ-F cards: 8861 BTU/hour (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules)

Configured with four CE98-D8DQ-F cards: 6248 BTU/hour (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules)

Number of power modules4
Redundant power supply2+2 backup
Rated input voltage [V]
  • 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC
  • 2200 W DC power module: –48 V DC to –60 V DC; +48 V DC
  • 2000 W high-voltage DC power module: 336 V DC
Input voltage range [V]
  • 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC
  • 2200 W DC power module: –38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC
  • 2000 W high-voltage DC power module: 260 V DC to 400 V DC
Maximum input current [A]
  • 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC)
  • 2200 W DC power module: 63 A (–48 V DC to –60 V DC); 63 A (+48 V DC)
  • 2000 W high-voltage DC power module: 10 A (336 V DC)
Rated output power [W]
  • 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V AC)
  • 2200 W DC power module: 2200 W
  • 2000 W high-voltage DC power module: 2000 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Power supply surge protection [kV]

AC: 6 kV in common mode and 6 kV in differential mode

DC: 4 kV in common mode and 2 kV in differential mode

HVDC: 4 kV in common mode and 2 kV in differential mode

Types of fansPluggable
Number of fan modules4
Redundant fansThe device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation modeAir cooling
Airflow directionBack-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
Availability0.9999932861
MTBF [year]25.50 years
Noise at normal temperature (27°C, sound pressure) [dB(A)]Back-to-front airflow: 60.6 dB(A) on average (maximum: 69 dB(A))
Noise at high temperature (40°C, sound pressure) [dB(A)]Back-to-front airflow: 78.2 dB(A) on average (maximum: 88 dB(A))
Long-term operating altitude [m (ft.)]≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating temperature [°C (°F)]

0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)

NOTE:

When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage altitude [m (ft.)]≤ 5000 m (16404 ft.)
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Storage temperature [°C (°F)]-40ºC to +70ºC (-40°F to +158°F)

CE9865-4C Warranty

Low Price Guarantee
Customers can get high quality products at wholesale prices

Quality Assurance
All products sold are original genuine goods, new packaging unopened

100% Money Back Guarantee
If your returns meet our relevent standards,you can contact our customer service team to exchange or return any product that you bought from us

Commodity Refund Guarantee
For equipment purchased from us, please contact our customer service team for return and replacement services

Diversified and Flexible Transportation Services
Cargo carriers include Fedex, DHL, UPS, Aramex, TNT, EMS

Standard Policy
1 Year