Huawei CE9855T-32DQ Switcg

CE9855T-32DQ
Price:US $435.00
Huawei CE9855T-32DQ Switcg
Huawei CE9855T-32DQ Switcg

Huawei CE9855T-32DQ Switcg

CE9855T-32DQ

CE9855-32DQ switch (32*400GE QSFP-DD, Without Fan and Power Modules)

New Factory Sealed
US$ 435.00
mastercard paypal t-t visa
Huawei CE9855T-32DQ Switcg
Engineer Team Support
7*24h Online
  • 763 412 7282
  • +86 010 82830816

CE9855T-32DQ Overview

CE9855-32DQ

CE9855-32DQ (02355YSE)

Overview

Table 4-208 Basic information about the CE9855-32DQ

ItemDetails
DescriptionCE9855-32DQ switch (32*400GE QSFP-DD, Without Fan and Power Modules)
Part Number02355YSE
ModelCE9855-32DQ
First supported versionV300R023C11
Other part numbers02355YSF(CE9855-32DQ switch (32*400GE QSFP-DD, 2*AC Power Modules, 6*Fans, Port-side Intake))
Short NameCE9855

CE9855T-32DQ Specification

Technical Specifications

Table 4-212 Technical specifications of the CE9855-32DQ

ItemSpecification
Dimensions with packaging (H x W x D) [mm (in.)]260 mm x 590 mm x 790 mm (10.24 in. x 23.23 in. x 31.10 in.)
Dimensions without packaging (H x W x D) [mm (in.)]
  • Basic dimensions (the depth excludes the parts protruding from the body): 43.6 mm x 442 mm x 600 mm (1.72 in. x 17.40 in. x 23.62 in.)
  • Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442 mm x 633.4 mm (1.72 in. x 17.40 in. x 24.94 in.)
Weight without packaging [kg (lb)]9.94 kg (21.91 lb), excluding optical modules, power modules, and fan modules
Weight without packaging (full configuration) [kg (lb)]12.78 kg (28.17 lb) (including AC power modules and fan modules but excluding optical modules. If the device supports multiple models of modules, the heaviest modules are used for the measurement.)
Weight with packaging [kg (lb)]15.16 kg (33.42 lb)
Weight with packaging (full configuration) [kg (lb)]18 kg (39.68 lb)
Chassis height [U]1 U
Installation TypeCabinet installation
Switching capacityTo obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
CPU16-core, 2 GHz
MemoryDRAM: 16 GB
NOR Flash64 MB x 2
SSD Flash4GB SSD
USB

It can be used for log backup and USB-based deployment.

This function is reserved.

Power supply mode
  • AC pluggable
  • DC pluggable
  • HVDC pluggable
Console portRJ45
Downlink Service interface32 x 400GE QSFP-DD + 2 x 10GE SFP+
Service port supporting the stack functionReserved function. This function is not enabled.
RTCSupported
Typical power consumption [W]

528 W (100% traffic load, copper cables on half of ports, normal temperature, dual AC power modules)

689 W (100% traffic load, short-distance optical modules on half of ports, normal temperature, dual AC power modules)

Typical heat dissipation [BTU/hour]
  • 1802 BTU/hour (100% traffic load, copper cables on half of ports, normal temperature, dual AC power modules)
  • 2351 BTU/hour (100% traffic load, short-distance optical modules on half of ports, normal temperature, dual AC power modules)
Static power consumption [W]453 W
Static heat dissipation [BTU/hour]1546 BTU/hour
Maximum power consumption [W]

943 W (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules)

1340 W (100% traffic load, long-distance optical modules on all ports, 40°C or 104°F, dual AC power modules)

Maximum heat dissipation [BTU/hour]
  • 3218 BTU/hour (100% traffic load, short-distance optical modules on all ports, normal temperature, dual AC power modules)
  • 4572 BTU/hour (100% traffic load, long-distance optical modules on all ports, 40°C or 104°F, dual AC power modules)
Number of power modules2
Redundant power supply1+1 backup
Rated input voltage [V]
  • 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC
  • 2200 W DC power module: –48 V DC to –60 V DC; +48 V DC
  • 2000 W high-voltage DC power module: 336 V DC
Input voltage range [V]
  • 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC
  • 2200 W DC power module: –38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC
  • 2000 W high-voltage DC power module: 260 V DC to 400 V DC
Maximum input current [A]
  • 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC)
  • 2200 W DC power module: 63 A (–48 V DC to –60 V DC); 63 A (+48 V DC)
  • 2000 W high-voltage DC power module: 10 A (336 V DC)
Rated output power [W]
  • 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V AC)
  • 2200 W DC power module: 2200 W
  • 2000 W high-voltage DC power module: 2000 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Power supply surge protection [kV]

AC: 6 kV in common mode and 6 kV in differential mode

DC: 4 kV in common mode and 2 kV in differential mode

HVDC: 4 kV in common mode and 2 kV in differential mode

Types of fansPluggable
Number of fan modules6
Redundant fansThe device supports 5+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation modeAir cooling
Airflow directionPort-side air intake
Availability0.9999934176
MTBF [year]26.01 years
Noise at normal temperature (27°C, sound pressure) [dB(A)]Back-to-front airflow: 63.5 dB(A) on average (maximum: 70.7 dB(A))
Noise at high temperature (40°C, sound pressure) [dB(A)]Back-to-front airflow: 83.5 dB(A) on average (maximum: 90.5 dB(A))
Long-term operating altitude [m (ft.)]≤ 5000 m (16404 ft.)
Long-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating temperature [°C (°F)]

0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)

NOTE:

When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage altitude [m (ft.)]≤ 5000 m (16404 ft.)
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Storage temperature [°C (°F)]-40ºC to +70ºC (-40°F to +158°F)

CE9855T-32DQ Warranty

Low Price Guarantee
Customers can get high quality products at wholesale prices

Quality Assurance
All products sold are original genuine goods, new packaging unopened

100% Money Back Guarantee
If your returns meet our relevent standards,you can contact our customer service team to exchange or return any product that you bought from us

Commodity Refund Guarantee
For equipment purchased from us, please contact our customer service team for return and replacement services

Diversified and Flexible Transportation Services
Cargo carriers include Fedex, DHL, UPS, Aramex, TNT, EMS

Standard Policy
1 Year