The Huawei AC6605-26-PWR-64AP is a high-performance, rack-mountable wireless access controller tailored for medium-to-large enterprises and campus networks. This pre-configured bundle includes the AC6605-26-PWR hardware unit with a factory-installed 64 AP management license.
It is equipped with 20 GE PoE+ ports, 4 GE Combo ports, and 2 10GE SFP+ uplink ports, delivering a forwarding capacity of 10 Gbit/s. Supporting 802.11a/b/g/n/ac Wi-Fi standards, it can manage up to 1024 APs (licensable) and 10,000 concurrent users. Featuring 1+1 redundant power supplies, robust security, and unified wired & wireless management, it provides a reliable and scalable solution for modern enterprise network deployments.
| Installation Type |
|
| Dimensions without packaging (H x W x D) [mm(in.)] | 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.4 in. x 17.4 in.) |
| Weight without packaging [kg(lb)] | 5.48 kg (12.08 lb) |
| Storage | NOR Flash 256 MB |
| Console port | RJ45 |
| Eth Management port | RJ45 FE |
| Maximum power consumption [W] | 85 W |
| Maximum heat dissipation [BTU/hour] | 290 BTU/hour |
| Power supply mode | Pluggable power supply |
| Rated input voltage [V] | 100 V to 240 V |
| Input voltage range [V] | 90 V to 264 V |
| Service port surge protection | 6 kV in common mode |
| Relationship between PoE and system power modules [W] | Pluggable power module, providing power for 24 GE ports, each of which complies with 802.3af/at Rated input voltage: 100–240 V AC; 50/60 Hz Maximum input voltage: 90–264 V AC; 47 Hz to 63 Hz Maximum output current: +12 V: 10 A; –53.5 V: 7.11 A Maximum output power: 380 W (PoE), 500 W (total) |
| PoE OUT | Supported |
| Maximum PoE output power [W] | 30 W |
| Redundant power supply | Power modules of the same type work in 1+1 redundancy. |
| Types of fans | Built-in |
| Maximum number of physical ports on the entire device | 20 x 10/100/1000BASE-T + 4 x COMBO + 2 x 10G SR/LR |
| Long-term operating temperature [°C(°F)] | –5°C to +50°C (23°F to 122°F) (From 1800 m to 5000 m [5905.51 ft. to 16404.20 ft.], the maximum ambient temperature decreases by 1°C [1.8°F] for every 300 m [984.25 ft.] increase in altitude.) |
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH |
| Long-term operating altitude [m(ft.)] | –60 m to +5000 m (–196.85 ft to +16404.20 ft) |
| Atmospheric pressure [kPa] | 53kPa - 106kPa ETSI 300 019-2-3 |
| Noise at normal temperature (acoustic power) [dB(A)] | < 36 dBA |
| Ground | Grounding |
| USB | Not supported |
| MTBF [year] | 56.4 year |
| MTTR [hour] | 2 hour |